LSG Home

Hours and Location

Search LSG

Alphabetical Index

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W-Z

Anatomic Path Procedures 

Antimicrobial Susceptibility Profile

Critical Values Table

Critical Values Policy

Normal Ranges

Collection & Transport

Patient Identification

Patient Preparation

Specimen Identification & Labeling

Specimen Collection

Specimen Transport

Phlebotomy Services

Customer Service

Compliance & Accreditation

Point of Care Testing

Pathology Clinical Services

Department of Pathology

FACTOR V (089-0008)
FACTOR VIII (089-0010)
FACTOR IX (089-0007)
FACTOR XI (089-0419)
FACTOR XII (089-0012)

CPT 4 Code: Factor V-85220; Factor VIII-85240; Factor IX-85250; Factor XI-85270; Factor XII-85280

Test Order Mnemonic: FACTOR V; FACTOR VIII; FACTOR IX; FACTOR XI; FACTOR XII

Applies To: Measures levels of factor/s that can be useful in diagnosing bleeding disorders and liver disease.

Lab: Hematopathology

Request Form: Hematology A

Collection: Routine venipuncture; discard 1st mL of blood or collect other tubes (EDTA, red-topped) prior to collecting sample in blue-topped (citrate) tube.

Storage Instructions: Factor V: 4 hours at 2-8 C;  Factor VIII: 2 hours at room temp, 4 hours at 2-8 C; Factor IX , XI, and XII: 3 hours at room temp.   If time from draw to receipt in the laboratory is to be greater than 4 hours, centrifuge the specimen; remove the plasma from red cells and snap freeze (-70°C) plasma. Snap frozen plasma is viable indefinitely.

Causes for Rejection: 3.8% sodium citrate tube, QNS, clotted, severely hemolyzed specimen, specimen greater than 4 hours old, identification error, sample processed and/or stored improperly.

Availability: Samples are accepted 24 hours per day at Sample Management, 5.136 McCullough Bldg.

Turnaround Time: STAT: 1 ½ hours;  ROUTINE: 4 hours

Special Instructions: Deliver sample to lab within ½ hour for best results. Accepted up to 4 hours from draw.

Specimen: Blood

Volume: 4.5 mL blood

Minimum Volume: call lab

Container: 3.2% Sodium citrate tube (light Blue top tube) [NOTE: 3.8% sodium citrate tubes will NOT be accepted.]

Reference Ranges: Factor V:  0.69 – 1.39 Units; Factor VIII: 0.47 – 1.70 Units; Factor IX: 0.76 – 1.58 Units; Factor XI: 0.61 – 1.34 Units; Factor XII: 0.39 – 1.67 Units

Test Method:  Electromagnetic Viscosity Detection

Interfering Substances: oral contraceptives, anticoagulant therapy

 Revised 10/10/07 by W.Russo, MT(ASCP) 

redbar600.gif (292 bytes)

A B C D E F G H I J K L M N O P Q R S T U V W-Z

 Anatomic Path Procedures       LSG Home

UTMB | Search | Directory | News | Employment | Contact | Sitemap 
UT System | Reports to the State | Compact With Texans | Statewide Search
 
This site published by Department of Pathology Clinical Services.
Copyright ©  2006  The University of Texas Medical Branch. Please review our privacy policy and Disclaimer and Internet Guidelines