INHIBITOR SCREEN (089-0006) CPT 4 Code: 85335 Test Includes: Screens for inhibitors of factors of the extrinsic and intrinsic systems or for the presence of circulating Lupus anticoagulants. Test Order Mnemonic: INHSCR Request Form: Hematology A Collection: Routine venipuncture; discard 1st mL of blood or collect other tubes (EDTA, red-topped) prior to collecting sample in blue-topped (citrate) tube. Storage Instructions: Viable for 4 hours at room temperature. If time from draw to receipt in the laboratory is to be greater than 4 hours, centrifuge the specimen; remove the plasma from red cells and snap freeze (-70°C) plasma. Snap frozen plasma is viable indefinitely. Causes for Rejection: QNS, clotted, severely hemolyzed specimen, specimen greater than 4 hours old, identification error, sample processed and/or stored improperly. Availability: Samples are accepted 24 hours per day at Sample Management, 5.136 McCullough Bldg. Turnaround Time: 4 hours Special Instructions: Deliver sample to lab within ½ hour for best results. Accepted up to four hours from draw. Specimen: Blood Volume: 4.5 mL blood Minimum Volume: Call Lab Container: 3.2% Sodium citrate tube (light Blue top tube) Reference Ranges: Negative (Correction of the patient’s PT and/or aPTT by the addition of Pooled Normal Plasma) Test Method: Electromagnetic Viscosity Detection Interfering Substances: Heparin, Coumadin Revised 10/10/07 by W.Russo, MT(ASCP) |
|