BORDETELLA DIRECT FLUORESCENT ANTIBODY TEST

Synonyms: Pertussis Direct Fluorescent Test

Lab: Reference Laboratory

Request Form: Microbiology

Collection: Collect nasopharyngeal swab; use flexible wire swab.

Storage Instructions: Room temperature

Causes for Rejection: Inappropriate source

Availability: Samples are accepted 24 hours per day at the Microbiology Processing Laboratory, Room 5.137 McCullough.

Turnaround Time: 1-3 days

Special Instructions: Nasopharyngeal (flexible wire) swabs may be obtained from the Microbiology Laboratory, Room 5.137 McCullough Building. This test is offered in conjunction with a Bordetella pertussis culture. DFA testing is less sensitive than culture and should not be the only test performed.

Specimen: Nasopharyngeal swabs

Container: Culturette

Revised 1/28/2000 by T. Friloux

redbar600.gif (292 bytes)

A B C D E F G H I J K L M N O P Q R S T U V W-Z

 Anatomic Path Procedures       LSG Home

UTMB | Search | Directory | News | Employment | Contact | Sitemap 
UT System | Reports to the State | Compact With Texans | Statewide Search
 
This site published by Department of Pathology Clinical Services.
Copyright ©  2006  The University of Texas Medical Branch. Please review our privacy policy and Disclaimer and Internet Guidelines