Employee Information  Agency staff, please use your assigned 4 digit ID. Core staff must use UTMB employee ID
Emp ID  First Last
     
Workplace  Using the appropriate selection box below, please select your area of workplace. Note: TDC, Agency, and Medical Students may be selected using the Hospital Service selection box.
 
 UTMB Clinics                                         
 Community Based Clinics                 
  
 RMCHP & WIC Clinics                   
 
 Hospital  Service                             
 

I have read the Stanbio Policy and Procedure  Yes

Click on START TEST to begin

Test Date:     

 START TEST

  

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. For waived testing, appropriate specimen (s) include:

serum
amniotic fluid
urine
a and c
 


                                                                                         

 

 

 

 

 

2. Acceptable test kit storage requirements include:

room temperature
refrigeration
freezing
a and b

                                                                                         

3. Given the sensitivity of the test (25 mIU/L of hCG), is it acceptable to draw a blood specimen and perform a serum pregnancy test if the urine test is NEGATIVE or QUESTIONABLE?

Yes, draw the blood, spin it down, and perform a serum pregnancy test using the the StanBio QuStick
No, serum pregnancy tests are not considered a CLIA Waived test. Compliant practice requires blood specimen is submitted to the laboratory for testing.

                                                                                         

 

 

 

 

 

 

4. A reportable and acceptable positive (+) result is depicted by the appearance of:

two lines (a Control line and a Patient line)
one line (a Patient line or a Control Line)
no lines

                                                                                         

5. How many drops of specimen are required to perform this test?

2 drops.
3 drops
4 drops
Test Strip is dipped in the specimen (urine) cup for 15 seconds, then layed on flat surface.

                                                                                         

6. When kept in sealed pouch, unopened test devices are good until :

30 days
60 days
expiration date on box

                                                                                         

7. The StanBio True requires a positive and a negative control is run

when a new kit is opened
once per week
once per month

                                                                                         

8. This StanBio True Kit requires maintenance of two QUALITY CONTROL LOGS: one for documenting Onboard QC (Control Line) and one for documentation of Liquid QC (POS and NEG) control solutions. 
BOTH QUALITY CONTROL LOGS MUST BE REVIEWED ________________ by the Test Site Manager for proper documentation, frequency, and kit performance.

once per week
once per month

                                                                                         

9. A patient test result may be reported even if the 'Control Line' does not develop/ appear.

TRUE
FALSE

                                                                                         

10. When using the StanBio True, results must be read in ____ minutes:

15 seconds
2 minutes
3 minutes