Our Treatment Machines:
Siemens PRIMUS
The Siemens PRIMUS is a dual modality
(photons and electrons) linear accelerator with multiple treatment
energies for each modality. Available photon energies are 6 MV and 18 MV.
Available electron energies are 6 MeV, 9 MeV, 12 MeV, 15 Mev, 18 MeV, and
21 MeV.
"All
PRIMUS systems are capable of variable configurations for both photon and
electron energies.
Additionally, all PRIMUS Linear Accelerators can be upgraded to
accommodate new treatment capabilities when clinical demands grow. This
offers all treatment centers the advantages of a PRIMUS system with the
versatility of energy ranges and options needed to provide the hospital or
clinic with the tools to provide optimal treatments.
All
PRIMUS systems offer the most compact design in the radiation therapy
industry, along with the greatest clearance between the patient and the
treatment head." -Siemens Medical Systems website.
This allows for more flexibility in
patient positioning to assist in delivering the best possible treatment.
The accelerator is equipped with a MLC
in place of the lower photon jaws for geometric conformal therapy and
delivery of intensity modulated radiation therapy (IMRT). This feature
allows the user to maintain the highest level of patient care.
(2) Siemens PRIMART
The Siemens PRIMART is a single modality
(photons) and single energy (6 MV) linear accelerator optimally suited for
intensity modulated radiation therapy (IMRT). In act, our PRIMART is used
almost exclusively for IMRT treatments. Again the standard lower jaws are
replaced by a MLC for use in the IMRT treatments. This negates the need
for tertiary collimation, which allows for greater clearance between the
accelerator and patient. This again leads to more flexibility in patient
positioning to assist in delivering the best possible treatment.
Nucletron
microSelectron
From the
Nucletron website,
"The microSelectron HDR is a High Dose Rate Afterloading System. The short
but highly active source enables conformal therapy for complex implants."
Radiation is delivered through precise placement of the unit’s Ir-192
source. The irradiation times are determined by the planning system to
deliver a dose distribution that satisfies the physician’s criteria.
"The microSelectron HDR is installed in more than 1000 radiation therapy
departments around the world. It has an excellent proven track record for
safety and reliability.
The microSelectron HDR is the perfect combination between capability,
efficiency and capacity."
-Nucletron website. |