“Hands-On”
IMRT TRAINING COURSE
The
University of Texas Medical Branch, Galveston,
Texas
For a copy of this
information,
download and print
this file
Upcoming Course Dates:
1st Quarter 2007
Course Description
This
course is designed for those who are tired of listening to endless
lectures regarding IMRT and are ready to get to work.
Ideally created for those users with Siemens linear accelerators,
ADAC/Philips P3IMRT treatment planning, LANTIS record and
verify system, and the Siemens Primeview delivery system, this course
gives the participants hands-on IMRT training with the above tools and
demonstrates the nuances of their integration into the clinic.
The course provides the participant with didactic sessions and
extensive labs detailing IMRT treatment planning, delivery, and quality
assurance. As such, the
information provided is ideally suited for physicians, physicists, and
dosimetrists who are beginning an IMRT program or introducing these tools
into their existing program.
Day
1: Thursday
Start
Stop
Session
Time
Time
Length
Topic/Event
8:00
AM
8:30 AM
0:30
Breakfast / Welcome and Overview of Course
8:30 AM
9:00 AM
0:30
Overview of IMRT - definitions and literature review
9:00
AM
10:00 AM
1:00
IMRT Delivery and Quality Assurance
Considerations in
your TPS model
Linear Accelerator
Performance Issues
MLC Quality
Assurance Issues
10:00
AM
10:15 AM
0:15
Break
10:15
AM
10:45 AM
0:30
LAB: perform QA measurements on machine
10:45
AM
12:15 PM
1:30
Forward Planning IMRT
Demonstration of
forward planning IMRT process
Hands-on
Treatment Planning: breast
12:15
PM
1:15 PM
1:00
Lunch
1:15
PM
3:15 PM
2:00
Inverse Planning IMRT – IA (Prostate)
Overview of
Pinnacle IMRT Planning Tools
Hands-on
Treatment Planning: prostate
Combined
Forward/Inverse Planning
Regions of
Interest for Prostate IMRT
3:15
PM
3:30 PM
0:15
Break
3:30
PM
5:30 PM
2:00
Inverse Planning IMRT – IB (Prostate)
Regions of
Interest for IMRT
ROI
Expansion/Contraction Tools
Dose
Objective/Constraints
Optimization
7:00
PM
Group Dinner
Day 2:
Friday
Start
Stop
Session
Time
Time
Length
Topic/Event
8:00
AM
8:30 AM
0:30
Breakfast
8:30
AM
9:30 AM
1:00
Fluence Map Segmentation
IMFAST
segmentation algorithm
LAB:
segmentation with IMFAST
9:30
AM
10:30 AM
1:00
Segment Weight Re-optimization
Evaluation of the
need
Revision of Dose
Objectives/Constraints
LAB: segment
weight re-optimization
10:30
AM
12:00 PM
1:30
Inverse Planning IMRT - IIA (Head and Neck)
Review of RTOG
Protocol H0022
Challenges of Head
and Neck IMRT with Pinnacle
12:00
PM
1:00 PM
1:00
Lunch
1:00
PM
3:00 PM
2:00
Inverse Planning IMRT - IIB (Head and Neck)
Hands-on
Treatment Planning: head and
neck
Regions of
Interest for IMRT - Head and Neck
ROI
Expansion/Contraction Tools
Dose
Objective/Constraints
3:00
PM
3:15 PM
0:15
Break
3:15
PM
4:45 PM
1:30
Completion of Treatment Planning
Setting the
Prescription
Plan printout
DRR creation and
printout
BEV printout of
each segment
Export of data
from TPS to R&V system
LAB: complete treatment plans
4:45
PM
6:15 PM
1:30
Plan Review and Approval
Data transfer from
TPS to R&V system
Creation of QA
fields
Hands-on
R&V Data Transfer and PrimeView
7:00
PM
Group Dinner
Day 3:
Saturday
Start
Stop
Session
Time
Time
Length
Topic/Event
8:00
AM
8:30 AM
0:30
Breakfast
8:30
AM
10:00 AM
1:30
IMRT Plan Validation - Part I (Phantom Study - TPS)
Treatment Planning
Process for Phantom Study
TPS for comparison
with measurements
LAB: create and document phantom study
10:00
AM
10:15 AM
0:15
Break
10:15
AM
12:00 PM
1:45
IMRT Plan Validation - Part II (Point dose and maps)
Dose Comparison
with Ion chamber or MOSFET
Verification of
Fluence Maps from Each Beam
LAB: Deliver IMRT Plan on Linac to chamber
12:00
PM
1:00 PM
1:00
Lunch
1:00
PM
2:30 PM
1:30
IMRT Plan Validation - Part III (dose distribution)
Utility of RIT113
Film Dosimetry System
Efficient creation
of H&D curve
Experimental
design for film study
Film processing
and conversion of OD to dose
LAB: Create
H&D curves in RIT
2:30
PM
2:45 PM
0:15
Break
2:45
PM
5:45 PM
3:00
IMRT Plan
Validation - Part IV (dose distribution)
LAB: Deliver IMRT Plan on Linac to film
Comparison of dose
distributions
LAB: measure
dose distribution and analyze
Interpretation of
Film/Plan comparison
Acknowledgment
UTMB
at Galveston acknowledges the support of Siemens Medical Systems, Oncology
Care Systems (Concord, CA) and Philips Medical Systems ROS Division
(Milpitas, CA).
Course
Director
Brent C. Parker, PhD
Assistant Professor
Department of Radiation Oncology
bcparker@utmb.edu
Contact
Information
Stephanie Daniels
Administrative Secretary and IMRT Coordinator
Radiation Oncology - Physics Dept.
UTMB - 301 University Blvd.
Galveston, Tx. 77555-0711, Rm 1.502
office 409-772-6383
fax 409-772-6373
srdaniel@utmb.edu
For a copy of this
information,
download and print this file |